| Battery Undervoltage Monitor BUW524 | |
![]() |
• Continuous measurement and display of voltage |
Download data sheets (.PDF) BUW524 10 - 33 VAC |
|
|
|
| Battery Undervoltage Monitor BUW112, BUW124 (discontinued) | |
![]() |
• Large setting range 10 - 14V / 20 - 28V |
Download data sheets (.PDF) BUW112 4-wire N 231V 50Hz +/-20% BUW124 4-wire N 231V 50Hz +/-4% |
|
Trigger unit for battery undervoltage protection, especially for monitoring the starter battery for diesel-driven generators. In the output, the unit has a two-way contact switched as a normally open contact. |
|
| Digital Frequency Monitor DFW100 | |
![]() |
• Two-stage frequency monitor with LCD digital display |
Download data sheets (.PDF) DFW100 231V 50Hz |
|
This unit is used for monitoring the frequency of an AC mains network, especially in free-running off-mains networks, combined heat and power stations and emergency power supplies. As the DFW100 records the connected frequency with high precision ( better than 0.05% ), the unit is also suitable for monitoring the mains frequency in interconnected networks. The frequency monitor has an easy-to-use menu interface with an LCD display. The settings can be reprogrammed by the user during operation of the unit. |
|
| Frequency Monitor AFW100 (discontinued) | |
![]() |
• Two-stage frequency monitor for 50Hz network application |
Download data sheets (.PDF) AFW100 231V 50Hz |
|
The unit is used for detecting the mains frequency or generator frequency, especially for frequency monitoring in free-running networks. The underfrequency relay is active at the rated frequency and the overfrequency relay is not switched through. The unit is supplied with an auxiliary voltage via the measuring voltage. |
|
| Speed Controller (Remanence Frequency Relais) 0,5–70Hz RFR500 | |
![]() |
• 2-way frequency monitoring with seperate output relay |
Download data sheets (.PDF) RFR500 0,5-70Hz 5-264VAC Auxiliary Voltage 24VDC |
|
The speed controller RFR500 is used to monitor the starting frequency and rated frequency of generators or gensets. With channel 1 the frequency will be monitored during starting of genset under low mains voltage until the start frequency ( 10-30Hz ) reached ( end of start ) by swiching of relay 1 (starting mashine will be stoped). The 2. channel monitors the rated frequency (50Hz) and is i.e. set to 49,9Hz. With this there is also a monitoring for underfrequency during normal running. The change of switchpoints for frequency, hysteresis or of switching delay (10ms – 60sec.) may be changes during normal running (easy programming) and will be used after storing into eeprom. The auxiliary voltage 24VDC will be get from battery, other supply voltages are available on request. |
|
| Asymmetrical Load Monitoring Unit SLW150 | |
![]() |
• 3-phase load current recording |
Download data sheets (.PDF) SLW150 3-phases with 5A (IR) each |
|
The unit is usually used for motor / generator protection in 3- or 4-wire AC mains networks. It records the current of each individual wire and compares them with the average value for all three phases. In the case of undershooting or overshooting of a phase in comparison with the deviation in % set ( 5-50% ), the internal time circuit is triggered on completion of which the relay switches through. |
|
| Rapid Voltage Monitor ASW500, ASW503 | |
![]() |
• Two-stage 3/4-wire phase voltage monitoring |
Download data sheets (.PDF) ASW500 4-conductor N 231V 50Hz ASW503 3-conductor 400V 50Hz |
|
Trigger unit for undervoltage and overvoltage protection in 3- or 4-conductor AC mains networks.Each phase is recorded individually and causes the two-way output contacts to be triggered in the case of undershooting or overshooting of the setpoint value. The switching state is displayed via LED`s. Special evaluation circuitry allows rapids recording of values while suppressing interference to a high degree. The undervoltage relay is switched as a normally open contact and the overvoltage relay is switched as a normally closed contact. |
|
| Threshold Time Relay GWZ100, GAZ100, GWG100, GWG200 (discontinued) | |
![]() |
• Input signal 0 - 20mA |
Download Datenblätter (.PDF) GWZ100 Pick-up current delay 0-20mA GWG100 Threshold indicator 0-20mA (GER) GWG100 Grenzwertgeber 0-20mA (GER) GWG200 like GWG100 for ext. setting (GER) |
|
Trigger unit for 20mA applications in 55mm standard housing. Available for pick-up current delay and drop-off time delay of the output relay contacts. The scaling of the adjuster for the threshold ( 0-20mA) can be read off in %. Under the designation of GWG..., the unit is offered as a threshold indicator with a continuously adjustable 0-20 mA signal as an output. |
|